HVLS Fans
We provide One-Stop Ventilation and Cooling Solutions for large spaces, including the king series, Paragon Series, Charm Series, Charm II Series, Virtue Series, and Grace Series.
- Home
- Blog
HVLS Fans Instruction
A high-volume low-speed (HVLS) fan, also called an industrial ceiling fan, big fan, or helicopter fan is a type of mechanical fan greater than 7 feet (2.1 m) in diameter. HVLS fans move air slowly and distribute a large volume of air at low rotational speed– hence the name “high volume, low speed.”
- HVLS Industrial Fan is a super larger energy-saving fan with a diameter of up to 7.3 meters (24ft);
- The airfoil Blade, which is developed with advanced technologies and principles of aerodynamics;
- A power of 1.5kw or less, that move a High Volume(13,800m³/min) of air at a Low Speed and cools up to 1000 square meters;
- Produce a large scale of natural wind, which leads to the double functions of ventilation and Temperature cooling, as well as dehumidification;
- The Ideal solution is to ventilation and cools the air in a large area.
HVLS Fans Superiority
How effective HVLS fan is?
Take an example you will understand well: An area of 1,000 square meters with a ceiling height of 10 meters, can be covered by one HVLS fan with a diameter of 24ft (7.3 meters), with 1.5 kW in power consumption, 828,000cmh airflow, at a noise level 43dB.
Amazing, right?
HVLS Fans Comparison
- Cover 1,500 M² per unit with 13,500m³/min, full space covered with its 7.3m diameter fan blade.
- Installation mounted to the ceiling, is simple and elegant.
- The tridimensional and natural breeze from all directions, with the most comfortable wind speed of 1-3m/s, with less noise.
- Almost zero maintenance after proper installation.
- 10-15 years.
- Wind can only reach the area in the front of the fan, and can not work well if people frequently move.
- Mounted on the wall or standing on the floor, need space to put or store, workshop limited using space effect.
- Mounted on the wall or standing on the floor, need space to put or store, workshop limited using space effect.
- noisy during operation long time exposure to high-speed wind will cause dizziness.
- 3-5 years.
| HVLS Fans | POWERFUL FAN |
---|---|---|
Fan Dia. (M/FT) | 7.3m/24ft | 0.75M/2.4FT |
Motor Power (KW/HP) | 1.5 | 0.36 |
Air Flow (m³/min) | 138,000 (828,000) | 300 (18,000) |
Effective Area (m²) | 1,500 | 300 |
Factory Area | 9,000 | 9,000 |
Total Units installed | 6 | 300 |
Total Kw Installed | 9 | 108 |
Consumption/Year | 28,080 | 336,960 |
HVLS Fans Applications
Typical applications for HVLS fans fall into two classifications—industrial and commercial. HVLS Fan can be installed in any big space which is higher than 4m.