Industrial Equipment

Built to Move More Air

Industrial HVLS fans, PMSM systems and evaporative cooling equipment for demanding large-space applications.

Virtue SeriesRTFANS product reference

HVLS Fans / Virtue Series

published

Virtue Series

Advanced industrial ceiling fans designed for warehouses, logistics centers and manufacturing plants.

SeriesVirtue Series
ModelRTF-SF-5EEX
CategoryHVLS Fans
Product record retained for engineering review and project selection.

Supplier rating on Alibaba: 4.9/5 based on 22 buyer reviews · Read buyer reviews

Product overview

Specification snapshot

Legacy record values shown as supplied
MPN / modelRTF-SF-5EEX
Airflow9,000
Rated power0.55 kW / 0.75 HP
Voltage220/380 V

Product record

Technical specifications

Virtue Series available product record specifications
MPNRTF-SF-5EEX
SKURTFSF5E01
Fan Dia.4.7 m / 16 ft
Power0.55 kW / 0.75 HP
Air Flow(m³/min)9,000
Voltage220/380 V
Rated current (220/380 V)2.2/1.3 A
Maximum application range550 m³
RPM40-80 RPM
Noise40 dBA
Weight55 kg
Fan Blades5 PCS
MotorNORD S1
Specification source2026 export configuration

Product context

About Virtue Series

Virtue Series is designed for large factories, warehouses and high-heat industrial spaces. Its controlled air movement helps equalize temperatures and reduce stagnant air in large occupied spaces.

9,000 airflowFresh-air evaporative coolingIndustrial spaces

Operating principle

How it works

3 steps
01

Move air downward

The suspended rotor moves a broad column of room air toward the occupied zone.

02

Spread air across the floor

Air moves outward from the fan and mixes warmer and cooler layers in the space.

03

Support comfort circulation

Air movement can improve perceived comfort, but the fan does not provide outdoor air or refrigeration.

Built for industrial use

Engineering features

Broad air movement

Large-diameter blades move room air across occupied zones and help mix temperature layers.

Facility-led layout

Ceiling height, structure, racks, lights and sprinklers affect the final fan position.

Mechanical safety review

Mounting, fasteners and secondary retention must follow the model installation instructions.

Routine service access

Inspect blades, fasteners, controls and drive components according to the model manual.

Selection data

Performance profile

Airflow
9,000
Rated power
0.55 kW / 0.75 HP
Application area
Needs confirmation
Water consumption
Needs confirmation

Before specifying

Operating notes

Cooling performance depends on entering air temperature, relative humidity and ventilation. The system performs best where cooled fresh air can move continuously through the space.

Service routine

Maintenance checklist

Before serviceIsolate electrical power and follow the model manual before inspection.

During routine checksInspect blades or impellers, guards, fasteners, safety retainers and controls according to the model manual.

Facility planning

Recommended applications

Airflow and Installation Details

Review the airflow pattern, control system, installation conditions and operating range for this fan.

Model and drive configuration

Virtue Series is represented by RTF-SF-5EEX in the 2026 export configuration. The source specifies NORD S1 and 5 PCS blades. The technical table lists the supplied model values, including diameter, airflow, power, voltage, current, speed, noise and weight.

Application range and installation

The source labels maximum application range in cubic meters (m³). This is a volume entry, not a floor-area rating in square meters. Select fan quantity and placement using mounting height, building dimensions, obstructions and the occupied zones. These fans circulate room air; outdoor-air ventilation and process extraction require a separate design.

Performance and service

Review the selected model's operating conditions and noise measurement method before quotation. Have a qualified installer check structural support, blade clearance, safety retainers and electrical supply. Isolate power before inspection and follow the supplied motor and controller manuals for maintenance.

Related guidance: HVLS Fans.

Related industrial equipment

View all in HVLS Fans

Facility planning

HVLS Fan FAQs

Can I use an HVLS fan to improve the air quality of my facility?

Yes. HVLS fans reduce humidity and distribute odor and smoke, providing healthy, fresh air.

Can these HVLS fans be mounted outdoors?

Traditional HVLS fans can't be mounted outdoors, but the portable series can. Moveable fans are indoor or outdoor flexible; suitable for gardens, gyms, playgrounds and so on.

Can the speed of the fan be adjusted?

Yes. A DANFOSS frequency converter with a step-less regulator varies the speed.

Do I need an HVLS fan if I already have an excellent HVAC system?

HVLS fans assist the HVAC system and spread cool air to every corner, so the AC does not need to run fully for as long.

How do I know that I need an HVLS fan?

If you have a large space and want better air-conditioning performance, air quality and ventilation, you need an HVLS fan. One fan can cover an area of up to 1,800 sq. meters depending on the size of the fan.

How long is the warranty on an HVLS fan?

RTFANS HVLS fans have a warranty period of three years.

What is the expected service life of HVLS fans?

10 years or more, depending on installation and use.

What fan sizes are available?

Diameter from 2.8 m to 7.3 m. Industrial HVLS fans: 3.7–7.3 m; commercial HVLS fans: 2.8–4.0 m; PMSM fans: 2.8–7.3 m. Applicable area 400–1,800 sq. meters.

Engineering selection support

Confirm whether Virtue Series fits your facility

Share floor area, clear height, roof structure, and operating conditions for a project-specific recommendation.